Guided Demo

Guided Demo · Milazzo study

Horizontal loop vs GAP Titan on 40 m — follow the reports and check the result.

What makes two WSPR reports comparable? And what can we learn from the reports that do not form a pair?

This guided demo revisits an early WSPR antenna study with a small enough sample to inspect ourselves. We will start with the published graphs, follow individual reports into WSPRadar, reproduce a few results, and then explore the wider analysis. Along the way, we will see why the WSPR cycle, grid locator and transmit power matter.

The focus is Station Insights. We use the study's selected path to follow WSPRadar's results back to individual reports and manually check the matching, calculations and summaries. We do not walk through every result: the later Global View and Segment Inspector sections provide optional context after the worked examples.

A spot is a WSPR reception report, and SNR means signal-to-noise ratio.

The two measures answer different practical questions. ΔSNR compares signal quality on matched observations. ΔDecode compares how many reports were actually recorded, including reception observed by only one setup. Understanding both helps you assess your own station.

KP4MD (CM98) / WB6RQN (CM98) · 40m · 19 December 2010, 12:00 – 20 December 2010, 20:00 UTC · RX Benchmark

Meet the experiment

In her 2011 study, Using the Weak Signal Propagation Reporter Network to Compare Antenna Performance, Carol Milazzo, KP4MD, compared a full-wave 40 m horizontal loop, about 5 m above ground, with WB6RQN's GAP Titan DX vertical. The stations were 29 km apart in the Sacramento area. VE6PDQ in Edmonton supplied the selected distant path. Read the original study.

The article examined both transmission and reception. It also recorded different operating schedules: WB6RQN used frequency hopping, while KP4MD remained on the frequency under study. Keep that difference in mind when we count reports.

In the table below, RX means reception and TX means transmission. Target and Reference label the two setups being compared; those labels stay fixed when we reverse who transmits and who receives.

Our replay covers 19 December 2010, 12:00 UTC to 20 December 2010, 20:00 UTC, on 40 m. KP4MD is always Target; WB6RQN is always Reference. Their roles change when we reverse the direction:

Example in this guide Who transmits? Who receives? What is compared?
Figure 6 reconstruction — RX VE6PDQ KP4MD and WB6RQN The two receiving setups observing the same remote transmission.
Figure 7 reconstruction — TX KP4MD and WB6RQN VE6PDQ The two transmitted signals observed at the same remote receiving-station entry.

A note on the historical labels: the original Figure 6 and 7 titles and captions assign the opposite directions to those established by the matching database records. This guide follows the database's transmitter and receiver fields and the reconciled directions in the comparison PDFs. The original images are retained unchanged. The website displays a dark color adaptation, with the white PDFs still available.

Start with Figure 6: what does the graph show?

Original Figure 6: cyan KP4MD and coral WB6RQN SNR traces over 19–20 December 2010. The reconstruction based on database records identifies these as reports received at the two compared stations.
Figure 6: original publication panel (dark adaptation)

Original Figure 6, retained from the publication. Reconciled direction: VE6PDQ → KP4MD / WB6RQN, an RX comparison. Select the image to open it at full size. Colors adapted for the dark website; the white PDF remains unchanged.

Read time along the horizontal axis and SNR vertically. A higher SNR means the signal stands out more strongly relative to noise. The cyan and coral traces show how reports from the two setups vary over the period.

The pattern invites comparison, but the dots do not all occur at the same times. The lines connect observations; they do not supply an SNR measurement between them. WSPRadar therefore checks which actual reports can be compared directly.

We will use the graph to choose what to inspect, then follow those observations into Station Insights. Checking the underlying reports lets us distinguish a visible trend from a directly measured difference.

The accompanying PDFs preserve the historical graphs, reconstruct observations from the database and show the paired results and reception counts:

Open WSPRadar and check the settings

This walkthrough is self-contained. Everything needed to understand the analysis is presented on this page, so you do not need to open the application. However, opening the prepared demo in a separate browser tab lets you follow along, inspect the results interactively and explore beyond the examples shown here.

Begin with a historical RX replay in WSPRadar. The RX button loads the respective RX settings. Review them, then select Run RX Analysis to start the historical replay. Later, repeat the historical comparison in TX mode with the same Target, Reference, band and time window.

Setting Value for these worked examples
First comparison Historical RX replay — RX benchmark
Target KP4MD
Reference WB6RQN
Band 40 m
Start 19 December 2010, 12:00 UTC
End 20 December 2010, 20:00 UTC
Reference SNR correction 0 dB
Time basis Local Solar at Target KP4MD / CM98

The sparse paired evidence remains available for inspection, including paths with a single paired observation. It allows us to check a calculation based on one observation; it does not establish a reliable typical advantage. For a new experiment, collect enough data to examine results with 3, 5 or 10 pairs per station, across repeated operating periods and several independent paths.

For this replay, Station Insights is our working area: it lets us keep the remote path fixed while inspecting the reports behind a result. The broader summaries can wait until we have checked these examples.

After the run, go to Station Insights. Leave Filter by selected segment and distance off so the list uses the completed analysis as its scope. The demo applies TX Station = VE6PDQ within that scope. We will start with VE6PDQ, then return to Global View and Segment Inspector to investigate the other paths.

Find the station: the locator is part of its identity

The demo opens Station Insights with TX Station = VE6PDQ already applied. The caption reads Station list: Filtered stations · 2 TX station identities · TX Station = VE6PDQ. The RX records contain two entries: VE6PDQ / DO34IR and VE6PDQ / DO34. The database writes the longer locator as DO34ir; the difference in letter case is immaterial. Open Filter to inspect, edit or clear the setting.

A station entry in WSPRadar identifies a remote station by its callsign and full reported grid locator. A callsign can appear from different locations, potentially hundreds or thousands of kilometres apart, invalidating many metrics and statistics. Keeping the locator prevents those reports from being automatically mixed into one path.

Here, DO34IR lies within DO34. These entries have different reported precision; they do not demonstrate that VE6PDQ moved, or that there were two physical VE6PDQ stations. WSPRadar nevertheless keeps their reported identities separate when matching and summarizing observations. This example illustrates why the reported locator is part of the matching rule, even when the entries may describe the same physical station.

VE6PDQ / DO34IR is selected initially. Selected Station Evidence follows that entry, with the selected-station time aggregation already set to 3h. In this RX comparison, VE6PDQ is the remote transmitter; KP4MD and WB6RQN remain the receivers being compared.

Which reports form a spot pair?

Pairing matters because propagation and noise can change with time. An SNR difference between reports from different cycles could reflect changing conditions as well as the setups. Pairing aligns the observation time and remote station; it does not make the two receiving installations or their conditions identical.

For this RX comparison, a spot pair occurs when both compared receivers report the same remote callsign-and-locator entry in the same two-minute WSPR cycle. We can then subtract their SNRs for that shared transmission.

A spot pair consists of one retained Target observation and one retained Reference observation matched on band, WSPR cycle, and the remote station’s callsign and full reported locator. Each pair supplies one ΔSNR observation.

When several reports exist for one setup, remote station, and cycle, WSPRadar consolidates them using its existing SNR-selection rules before forming the comparison.

If only KP4MD reports that entry in the cycle, it is Target-only. If only WB6RQN reports it, it is Reference-only. A station may supply paired observations in some cycles and one-sided observations in others.

These one-sided reports still document reception. They have no second measured SNR to subtract, so they contribute to ΔDecode rather than paired ΔSNR. A missing report does not reveal whether the other setup failed to decode, was operating elsewhere, or did not upload a report.

The paired result therefore describes only the subset observed by both setups; we will examine the remaining reception separately.

Follow one pair into ΔSNR

Figure 6 reconstruction with five exact same-cycle comparisons connected to the paired ΔSNR panel. The accepted differences are +8, +17, +22, +7 and +7 dB.
Figure 6: reconstruction and exact pairs

The reconstruction's upper plot uses the common 37 dBm scale; the table below uses 30 dBm. Both sides shift by the same 7 dB in this RX example, so ΔSNR is unchanged. In the lower panel, colour shows relative spot-pair density. Read the dB tick labels on its nonlinear vertical axis. Exact-observation circles and bin-median markers can represent the same evidence.

We now have a matching rule to check. Start with one pair, reproduce its subtraction, then compare it with the rest of the accepted sample.

With VE6PDQ / DO34IR selected, open Drill-Down Data and inspect 19 December at 14:46 UTC. Check the time and locator before comparing the SNR values.

Drill-Down Data shows the normalized SNR values (−5 and −13 dB for this pair). The raw reported SNRs and transmit powers used below are available in the verification ledger.

Power normalization puts the reported SNRs on a common transmit-power basis. This arithmetic adjustment uses the reported transmitter power; differences in receiver hardware and local noise remain part of the comparison.

The two SNRs recorded in the database are +2 dB at KP4MD and −6 dB at WB6RQN, for VE6PDQ transmitting at a reported 37 dBm, approximately 5 W. On the common 1 W / 30 dBm basis used for the paired comparison, both SNRs are reduced by 7 dB, becoming −5 dB and −13 dB.

ΔSNR = Target SNR − Reference SNR = −5 − (−13) = +8 dB.

The positive sign favors KP4MD. For this one shared transmission, its reported signal-to-noise ratio was 8 dB higher. The comparison concerns the installed receiving setups, including their antennas, receiver chains and local noise conditions.

In this RX pair, both receivers observed the same transmission, so the same power adjustment applies to both SNRs and leaves their difference unchanged. When we switch to TX, the two transmit powers will differ.

The Figure 6 reconstruction lets us follow all accepted pairs. Dashed guides connect the reports in the upper plot with their ΔSNR observations below.

Switch between VE6PDQ / DO34IR and VE6PDQ / DO34 to check the five pairs. Each selected-station view contains only its own locator entry.

UTC VE6PDQ locator Target SNR at 1 W Reference SNR at 1 W ΔSNR
19 Dec, 14:46 DO34IR −5 dB −13 dB +8 dB
20 Dec, 07:46 DO34 −12 dB −29 dB +17 dB
20 Dec, 09:04 DO34IR −12 dB −34 dB +22 dB
20 Dec, 15:24 DO34 −13 dB −20 dB +7 dB
20 Dec, 15:46 DO34IR −17 dB −24 dB +7 dB

All dates are in 2010. Values are power-normalized for comparison, rather than the raw SNRs at which decoding occurred. Six-pair verification ledger, including database record IDs.

Sorted from lowest to highest, the five differences are 7, 7, 8, 17, 22 dB. Their median—the middle value—is +8 dB.

All five spot pairs favor KP4MD's receiving setup, but their differences vary from 7 to 22 dB. That supports a consistent direction within this small sample. It does not establish a constant 8 dB advantage throughout the 32-hour window.

Keep the scope of each summary clear:

Selected evidence Spot pairs Median ΔSNR
VE6PDQ / DO34IR 3 +8 dB
VE6PDQ / DO34 2 +12 dB
Both entries' individual pairs pooled, as in the PDF 5 +8 dB

With an even number of observations, the median averages the two middle values; DO34's +12 dB therefore summarizes its +7 and +17 dB pairs.

The PDF's +8 dB line summarizes the five individual pairs as a median. The map instead pools qualifying paired differences within each segment, giving each pair equal weight. Its mean and CI match the pooled Spots result only for the same qualifying pairs, SNR adjustments and confidence level; the existing station minimum and additional CI precision requirement govern coloring. Their summary statistic and population differ; the pooled five-pair result is not an all-station result or automatically a map result.

Why the locator matters here: what changes if we match on callsign alone?

A separate check of these same database records finds three additional same-cycle comparisons if the locator is ignored. In each, one receiver reports VE6PDQ as DO34 and the other as DO34IR. They do not meet the exact callsign-and-locator matching rule.

Including those cross-locator comparisons would change five pairs to eight and the pooled median from +8 dB to +11.5 dB. This is a different matching assumption, not a correction to WSPRadar's result. The extra comparisons are not proven physically unrelated transmissions; their reported identities differ.

The same endpoint reports still total 31 at KP4MD and 13 at WB6RQN, so their overall report-count ratio is unchanged. What changes is which observations count as Paired and which enter paired ΔSNR. Identity is part of the measurement definition, not just a label on a map.

Inspect the three cross-locator comparisons and their database IDs.

Count what else was heard

Observed RX coverage for VE6PDQ at DO34IR, showing Paired, KP4MD-only and WB6RQN-only events in three-hour bins, with the decode factor on the right axis.
Figure 6: VE6PDQ / DO34IR observed RX coverage

VE6PDQ / DO34IR only. The final interval is 18:00–20:00 UTC. Full bin counts and the separate DO34 entry are on page 2 of the linked PDF.

So far, we have compared signal quality only where both receivers supplied a measurement. We now count all retained reports for the selected entry, including those that cannot form a pair. In this view, we will read the report-count comparison on the fold scale.

Return to VE6PDQ / DO34IR and open its ΔDecode over Time. Use 3h to match the reconstruction's time bins. This historical reconstruction retains UTC: select Time basis: UTC in the selected-station controls for the 15:00–18:00 UTC example below, then restore Local Solar when exploring that station’s temporal views later. This station-level change leaves the segment clock unchanged.

The spot-level colours show three outcomes: Paired in green, Target-only in magenta, and Reference-only in cyan. A three-hour bin groups observations for display; pairing still uses the individual WSPR cycle and station identity.

Across this entry's full window, there are 8 Target-only, 3 Paired and 5 Reference-only observations. Each paired observation contributes one report to each receiver:

Receiver Reports counted Total
KP4MD — Target 8 Target-only + 3 Paired 11
WB6RQN — Reference 5 Reference-only + 3 Paired 8

11 ÷ 8 = 1.38×: KP4MD recorded 1.38 times as many reports from this station entry. This is an observed decode-count ratio. It is not the fraction of all attempted transmissions successfully received; cycles with no report from either receiver are absent from this evidence.

The line uses the right-hand fold scale: 1× means equal counts; values above or below it name the favored side. Exclusive means only one side was observed in that bin. A blank bin has no retained observations, so it supplies no ratio.

The colours also explain why the SNR plot contains so few points. Many cycles produced a report at only one receiver. Those observations add reception evidence even though they cannot add a paired SNR difference.

For a useful check, look at 19 December, 15:00–18:00 UTC. Each receiver has one report, giving 1×, but there are zero spot pairs. Both heard this station entry within the bin, at different times. Equal counts do not create a matched SNR measurement.

The separate DO34 entry contributes 20 versus 5 reports. Adding the two entries gives 31 versus 13, or 2.38×, for the selected RX path as represented in the PDF. Selecting either entry alone in WSPRadar will show its own evidence.

Reverse the direction: Figure 7

Run in WSPRadar App · TX ↗
Original Figure 7, with adapted display colors: coral WB6RQN and cyan KP4MD SNR traces. The reconstruction based on database records identifies these as transmissions received at VE6PDQ.
Figure 7: original publication panel (dark adaptation)

Original Figure 7. Reconciled direction: KP4MD / WB6RQN → VE6PDQ, a TX comparison. Colors adapted for the dark website; the white PDF remains unchanged.

The RX example asked what the two local setups heard from the remote station. Now we ask what that remote station heard from them. We will repeat the same sequence: check the selected identity, inspect a pair, then count the remaining reports.

Before switching to TX, save the RX results: under Download & Share Results, select Prepare All Results for Download, then Download Prepared Results. Use Save Config to retain the RX settings too.

Use Run in WSPRadar App · TX beside this section heading to run a historical TX benchmark for the same Target, Reference, band, dates and other settings. The prepared TX link filters Station Insights to VE6PDQ and preselects VE6PDQ / DO34IR. VE6PDQ is now the remote receiver reporting the two compared transmitters.

For a TX spot pair, the same remote receiving-station entry must report both compared transmitters in the same WSPR cycle. This aligns the receiver and observation time. It does not remove differences between the transmitting installations.

The selected TX records contain 76 reports but only one spot pair. Open Drill-Down Data at 20 December, 00:22 UTC to inspect it. Its normalized SNR columns show −20 and −18 dB; the raw values and reported powers in the following table come from the linked verification ledger.

Check transmit power before subtracting SNR

In TX, the two signals come from different transmitters, so their reported SNRs can reflect different transmit powers. We therefore need to check the power adjustment for each side separately.

KP4MD's reports specify 37 dBm, approximately 5 W; WB6RQN's specify 33 dBm, approximately 2 W. To compare their SNR on a common power basis, WSPRadar accounts for that reported power difference.

Transmitter Raw reported SNR Reported TX power SNR on the common 1 W basis
KP4MD — Target −13 dB 37 dBm −20 dB
WB6RQN — Reference −15 dB 33 dBm −18 dB

Raw subtraction would give +2 dB. On the common power basis, ΔSNR = −20 − (−18) = −2 dB, favoring WB6RQN for this one paired observation.

That change of sign shows why the power basis matters. In the PDF's common 37 dBm presentation, the same pair is −13 versus −11 dB and still gives −2 dB. The detailed scale reconstruction remains in the linked PDF.

One pair can verify a calculation, but cannot establish a typical TX advantage or a time trend. A median marker and the exact observation may both appear in the chart; they still represent one pair.

Why the nearby points do not form another pair

Figure 7 reconstruction showing all 76 database reports. An annotation identifies KP4MD at 10:34 and WB6RQN at 10:36 on 20 December as nearby observations from different cycles.
Figure 7: reconstructed database reports

Once the accepted TX pair is clear, check why an apparently similar part of the graph contributes no additional pair. Visual closeness alone does not tell us whether the observations meet the matching rule.

Look at 20 December, 10:34 UTC for KP4MD and 10:36 UTC for WB6RQN. They have equal SNR after power normalization, but belong to different cycles. They therefore supply no paired comparison.

This is what same-cycle pairing means here: use the same WSPR cycle, rather than moving timestamps, pairing the nearest dots or subtracting the connecting lines. The unpaired observations remain useful in the reconstructed traces and in the reception counts.

Compare signal margin with the recorded decodes

Open the selected receiver's ΔDecode over Time. Across the window, VE6PDQ reported 57 KP4MD transmissions and 19 WB6RQN transmissions: 3× as many Target reports. They comprise 56 Target-only, 1 Paired and 18 Reference-only events. See the full TX coverage plot and bin counts.

The one paired SNR result favors Reference; the total count favors Target. Each result describes its own evidence: comparable signal levels on one matched observation, and accumulated reports across the window.

The decode counts retain the actual transmit powers and operating schedules. Normalizing SNR does not change how many reports were received. Here, 5 W versus 2 W and the documented frequency-hopping difference prevent us from attributing the 3× count ratio to the antennas alone.

Expand from VE6PDQ to the other observed paths

The central Station Insights walkthrough is now complete. The following sections are optional orientation: they show where to explore the same questions across more paths, without reviewing every result in this run.

We have checked one remote callsign, with two RX locator entries and one TX receiving entry. Now ask whether its pattern appears elsewhere in the same analysis.

Keep the current analysis mode explicit: in RX, the remote entries are transmitters; in TX, they are receivers. The figures and numbers above concern VE6PDQ only. The wider views combine the other retained station entries too.

Global View: where is there paired evidence?

The first wider question is geographic: where do we have paired signal measurements? A segment groups station entries by direction and distance; its support tells you how much retained evidence contributes.

Open the ΔSNR map. Read a segment's direction, distance, pooled mean paired ΔSNR, CI and supporting pair and station counts together. A positive value favors KP4MD; a negative value favors WB6RQN.

Each qualifying station entry contributes all its eligible paired differences within the segment. The map pools those pairs with equal pair weights, then computes the mean and its nominal IID Student-t CI from sample SD and pair count N. The configured station count and maximum unrounded CI half-width both determine coloring. A frequently observed entry therefore has more influence when it supplies more pairs. Check how many entries support the segment, remembering that different locator entries do not necessarily represent different physical stations.

A hatched segment fails its configured station minimum or pooled-pair CI requirement. The default for a new analysis is three qualifying stations; this demo uses its stored count. A one-station segment can meet a station minimum of one, but a non-degenerate pooled CI requires at least two pairs with some variation between their ΔSNR values. The CI must also be available and its unrounded half-width must meet the selected limit. With two or more contributing pairs, all-identical paired differences retain a zero-width numeric interval with degenerate status and remain hatched. Eligible observations in hatched segments remain in Inspector scope statistics. It need not mean that no signals were heard there. The decoding view can still contain reception evidence from that direction.

Decodes & Stations by SNR Cutoff: what does the paired sample leave out?

The map’s ΔSNR values summarize matched observations; the next question is how much reception lies outside that paired sample. These curves build up the totals of decoded spots and distinct station entries as progressively lower-SNR successful reports are included. One-sided reports add reception recorded for only one setup for a given remote station and WSPR cycle, which cannot enter paired ΔSNR.

Open Global View → Decodes & Stations by SNR Cutoff. Read from stronger signals on the left toward weaker signals on the right. The upper row accumulates reports; the lower row accumulates distinct station entries. These curves use each side's raw reported SNR, rather than the common-power values in our paired calculation.

In Paired spots, the two report curves end at the same count: each accepted pair contains one retained observation from each side. Separation before the endpoint describes different reported SNRs for shared observations. One-sided spots add the reports heard by only one side in their respective cycles.

Ask whether additional reports mainly repeat paths already observed, or also add station entries. A station can contribute both paired and one-sided reports, so extra one-sided spots do not automatically mean extra stations. If the station panels show Both observed, no pairs, those entries were heard by both sides during the window, but never in a shared cycle.

Notice where one-sided reports enter along the SNR axis. Extra weak reports can be consistent with additional reception margin, but this historical comparison also contains different powers and operating opportunities. The curves do not establish why any particular report is missing.

ΔDecode map: where were more reports recorded?

Having looked at signal levels, return to geography and ask where the report totals differ. This extends the selected-station count check to the wider set of retained paths.

Open the ΔDecode map and compare the same directions and distances as on the SNR map. Its fold labels express observed report-count advantage, with 1× representing parity. Check which side the legend favors and how much evidence supports the segment.

The segment pools the observed counts; it does not average individual stations' ratios. Both maps can agree, or they can emphasize different paths because paired signal quality and total observed reception use different evidence. Use the support information before giving a large factor much weight.

Segment Inspector: is the summary representative?

A map gives a summary for an area. The next question is whether that summary reflects similar results across its contributing stations, or a broad spread of different outcomes.

Start with Segment Inspector → Full Range | All Directions to inspect the wider sample, then select a geographic segment if you want to narrow the question.

In Benchmark Statistics, compare the distribution of station results with that of individual paired observations. Station summaries give each qualifying entry one value; the spot-pair summary gives more influence to paths that contributed more pairs. Look at the distribution and sample size as well as the median. The station-means panel and Stations card show the same mean of station means and its aggregate CI; the station-median panel describes a separate quantity. The Figure 6 and Figure 7 paired calculations have their own published or reconstructed numerical provenance; keep their populations and statistics named when comparing them with the map or the Stations summary.

The five-pair Figure 6 median already showed how a small sample can hide considerable variation. A narrow-looking distribution based on very few observations is not evidence of a precisely established antenna advantage.

Both temporal views: does the pattern persist?

We have asked where the evidence lies and how widely the results vary. Now check when those observations occurred, so gaps or a brief cluster are not mistaken for a persistent pattern.

Open ΔSNR over Time and ΔDecode over Time for the same scope. Check where paired measurements exist, how their differences vary, and whether reception continues through one-sided reports when the SNR evidence disappears.

Inspect the chronological view before the profile by Local Solar hour. Set the segment and selected-station controls separately to Time basis: Local Solar, the Milazzo demo's configured choice at Target KP4MD / CM98. Each choice applies to that level’s chronological and folded panels. Milazzo also starts both levels with ΔSNR statistic: Median; the choices remain independent. This run spans only 32 hours, so an hourly profile contains very few repetitions of each hour. Change Time aggregation to examine the chronological evidence more closely; larger bins combine observations but do not create new pairs or additional operating time. The folded panel retains fixed one-hour bins.

12:00 is solar noon. Local Solar uses local apparent solar time at the Target QTH, including the date-dependent equation of time; it is neither civil clock time nor daylight-saving time. Matching solar hours are combined across the selected dates. Switching Time basis to UTC changes the displayed clock in both temporal views at that level; the other level keeps its own clock. Chronological bins keep the same UTC boundaries, observations and statistical values. The folded panel regroups the same observations by the selected date and hour before aggregation, so its hourly summaries can change. Pairing, qualification and whole-window totals remain unchanged. Input boundaries, source-report timestamps, verification tables and the original publication reconstructions remain in UTC. The solar reference describes the Target location, not VE6PDQ or the whole propagation path.

Where station-level and spot-level coverage are shown, distinguish their questions. A station can be observed by both sides within a bin at different times; a spot-level Paired event requires the same cycle. The equal-count, zero-pair RX example demonstrated that difference.

Finally, return to Station Insights and clear the VE6PDQ callsign filter through Filter. Choose another entry with a clear purpose—more paired evidence or a different result—and follow it into Drill-Down Data. Use Include one-sided evidence if you also want to list entries without paired observations. Check the chart's selected identity and scope before comparing it with VE6PDQ.

What does WSPRadar add to the historical comparison?

Whether you followed the optional wider views or stayed with VE6PDQ, the main check is the same: connect the selected source records to the matched observations, arithmetic and report totals.

The reconstructed traces retain the observed changes and gaps that made the original study informative. The complete PDFs explain their correspondence with the published figures and the power scales used. The database also lets us inspect exact timestamps, reported locators and records that a plotted line cannot explain by itself.

WSPRadar adds explicit matching, separate treatment of one-sided reception, and summaries whose contributing observations can be inspected. We have independently checked the six accepted pairs and the reception totals against the database records. This verifies the arithmetic and grouping for these selected examples; it does not establish every paper-marker correspondence or validate all possible analysis cases.

The RX observations favor KP4MD's receiving setup in all five accepted comparisons. The TX sample contains just one common-power comparison, favoring WB6RQN by 2 dB. Those small, differently sampled sets do not demonstrate an antenna advantage reversing between transmission and reception. Their value here is that we can follow precisely what each result measures.

Save the evidence and apply the method to your own station

You can now follow a result back to its reports: identify the stations and locators, check the cycle, compare SNR on the appropriate basis, and count the reception outside the paired sample. Use that same sequence whenever a map colour or a large difference catches your attention. We can now account for the selected-path results:

Evidence checked Paired signal-quality result Observed reception
RX, both VE6PDQ locator entries Five pairs; pooled median +8 dB for KP4MD 31 versus 13 reports, or 2.38× as many at KP4MD
TX, VE6PDQ / DO34IR One pair; −2 dB on a common power basis 57 versus 19 reports, or 3× as many for KP4MD

These results become useful because we know their identities, timing, power basis and support. The sparse matched sample and differing operating opportunities limit the antenna conclusions, while leaving the individual calculations fully checkable.

For this manual check, the companion files include the 120 endpoint reports from the database, their record IDs, the six-pair ledger, and the identity-specific and three-hour count tables:

Use the companion files for the record-level check and the results package to preserve the app run.

Under Download & Share Results, select Prepare All Results for Download, then Download Prepared Results, to preserve the configuration, figures and processed observations in the results package. Save Config separately preserves the reusable analysis settings; Share Analysis also preserves those settings by encoding them into the URL. For your own experiments, keep station notes alongside it so a later comparison includes what was physically connected, when both setups were operating and what changed.

Run this comparison in WSPRadar ↗